Modern villa with large aluminium windowsBuilding with aluminium windows and brick claddingHigh-rise tower with glass curtain wall
Service · Window, Door & Sliding Systems

Structural calculation for aluminium windows, doors and sliding systems

For high-rise buildings and large openings, windows are no longer a catalogue choice. We verify profiles, reinforcement, glass and hardware against the actual wind load.

Structural calculation for aluminium windows, doors and sliding systems
Schematic · Window, Door & Sliding Systems

Why it matters

Catalogue values usually assume standard sizes and a specific wind class. On tall buildings, coastal sites or sliding sashes over three metres, they may not be enough. The result is excessive deflection, sashes that will not close, and air and water leakage.

We check wind load, frame and mullion deflection against the EN 12210 class (A: L/150, B: L/200, C: L/300), reinforcement, glass thickness and hardware capacity for heavy sashes.

Systems

  • Thermally broken windows and doors
  • Lift-and-slide and minimal sliding systems
  • Folding doors
  • Shopfronts
  • Export projects requiring EN 14351-1

Standards

  • EN 1991-1-4
  • EN 14351-1
  • EN 12210
  • EN 1999-1-1
  • DIN 18008

Quick quote

Send drawings and the project address; we will define the scope together.

Send project details
Scope

What we check

01

Wind load

Design pressure by height and location, including corner zones.

02

Deflection

Relative frontal deflection by EN 12210 class plus stress checks.

03

Reinforcement

Required inertia and steel or aluminium reinforcement.

04

Glass

Glass thickness for wind load and pane size.

05

Hardware

Track, roller and hinge capacity for heavy sashes.

What we need

Information for a quote

  • Window schedule or elevations
  • System and profile series
  • Location and storey height
  • Glass build-up
  • Wall type
What you get

Deliverables

  • Check table per window type
  • Reinforcement and glass recommendations
  • Fixing details where needed
  • Reports in English
FAQ

Window, Door & Sliding Systems

Do you calculate every window separately?

No. We group positions by span and load and calculate the governing cases, then report results for all positions in one table.

Building with aluminium windows and brick claddingHigh-rise tower with glass curtain wallModern villa with large aluminium windows

Let’s talk about your project

Send drawings, elevations and system information; we will define the scope and timeline and get back with a quote.