Curtain wall structural calculation and facade structural reports
Stick, unitised and structural-glazed facades: we calculate the full load path from wind pressure to the anchor and deliver a structural report that reviewers can follow.
Why it matters
A facade calculation is more than proving that a profile works. Wind pressure and suction, glass weight, thermal movement, storey drift and connection details have to be checked together. A wrong bracket or an unchecked anchor can make even the right profile unsafe.
Every report states its assumptions, the standard used and the limit each result is compared with. We work to Eurocodes with the relevant national annexes and to Turkish standards (TS 498) for projects in Türkiye.
Systems
- Stick curtain walls
- Structural silicone glazing
- Unitised facades
- Rainscreen and cladding substructures
- Skylights, canopies and glass roofs
Standards
- EN 1990
- EN 1991-1-4
- EN 13830
- EN 1999-1-1
- EN 1993-1-8
- EN 1992-4
- DIN 18008
- TS 498
Quick quote
Send drawings and the project address; we will define the scope together.
Send project details WhatsAppWhat we check
Wind load
Pressure and suction by height, terrain category, corner and edge zones (EN 1991-1-4 / TS 498).
Mullions
Support conditions, deflection limits of EN 13830, bending and shear; composite inertia for thermally broken profiles.
Transoms
Biaxial bending under wind and glass dead load, torsion and setting-block deflection.
Glass
Stress and deflection of insulating and laminated glass.
Brackets and connections
Aluminium and steel brackets, welds and bolts (EN 1999-1-1, EN 1993-1-8).
Anchors
Tension, shear, edge distances and cracked concrete with manufacturer software and ETA data.
Information for a quote
- Elevations and sections
- System catalogue or section properties
- Glass build-up
- Project location, height and surroundings
- Supporting structure details
Deliverables
- Structural calculation report (PDF, English)
- Profile, glass, bracket and anchor check tables
- Optimisation proposals where needed
- Responses to reviewer comments
Curtain Wall Structural Calculation
Can you work to the national annex of my country?
Yes. We prepare calculations to the Eurocodes with the national annex of the project country and state all parameters clearly in the report.
What do you need for a quote?
Elevations, storey heights, project location and the system name are usually enough for a first quote.
Related tools and articles
Related structural calculations
Window, Door & Sliding Systems
Large windows, lift-and-slide and folding doors: profiles, reinforcement, glass and sash weight.
Details →Glass Balcony & Guillotine Glass
Folding glass balconies and guillotine glass: wind, glass thickness, tracks and anchors.
Details →Structural Glass Calculation
Facade, roof, balustrade and floor glass: stress, deflection and climatic loads on IGUs.
Details →Glass Balustrade Calculation
Channel-clamped and point-fixed balustrades: line load, laminated glass and anchors.
Details →Skylights, Glass Roofs & Canopies
Skylights, glass roofs and suspended canopies: snow, wind, overhead glass and supports.
Details →Cladding Substructures
Aluminium substructures for ACP, ceramic, HPL, stone and metal panel cladding.
Details →Let’s talk about your project
Send drawings, elevations and system information; we will define the scope and timeline and get back with a quote.