Code tables cover rectangular buildings and simple roofs. For curved facades, canopies, pergolas and the influence of neighbouring buildings we determine wind pressures with computational fluid dynamics (CFD).

CFD wind analysis for facades, roofs and canopies
Schematic · CFD Wind Analysis

Why it matters

EN 1991-1-4 allows wind tunnel testing or validated numerical methods for geometries outside its scope: curved or stepped towers, large cantilever canopies, open and semi-open pergolas, louvres, and closely spaced tall buildings.

We model the flow around the building, extract the pressure distribution (Cp) and convert it into design pressures ready for the structural calculation, compared against code values and published reference studies.

Systems

  • Curved or stepped high-rise facades
  • Large canopies
  • Open and bioclimatic pergola roofs
  • Louvres and perforated facades
  • Building clusters
  • Rooftop PV and signage

Standards

  • EN 1991-1-4
  • EN 1990
  • TS 498
  • CFD best-practice guidelines

Quick quote

Send drawings and the project address; we will define the scope together.

Send project details
Scope

What we check

01

Flow model

Inflow profile for terrain roughness, domain and mesh study.

02

Wind directions

Analysis for selected directions and envelope values.

03

Pressure coefficients

Cp maps on facades and roofs, corner suction zones.

04

Design pressures

Conversion to design loads with EN 1991-1-4 peak velocity pressure.

05

Validation

Comparison with code values and reference studies.

What we need

Information for a quote

  • 3D model or drawings of building and surroundings
  • Location and terrain
  • Elements to study
What you get

Deliverables

  • Cp maps
  • Design pressure tables by zone
  • Flow visualisations and method statement
  • Integration into the structural report
FAQ

CFD Wind Analysis

Does CFD replace wind tunnel testing?

For very tall and unusual towers wind tunnel testing remains the reference. CFD is a strong tool for design-stage comparisons, non-standard small and mid-size structures, canopies and pergolas.