Bolt, screw, rivet and weld connection calculation
Fasteners in aluminium systems are often chosen by habit. We calculate bolts, screws, rivets and welds to the relevant standard and propose safer, economic solutions.
Why it matters
Aluminium differs from steel: pull-out and bearing in thin walls can govern, and welding reduces strength in the heat-affected zone (HAZ). Stainless bolts on aluminium need isolation against galvanic corrosion.
We check bracket-profile, profile-profile and steel-aluminium connections and verify critical details with FEM.
Systems
- Stainless and galvanised bolted joints
- Self-drilling and tapping screws
- Blind rivets
- Welded aluminium and steel brackets
Standards
- EN 1999-1-1
- EN 1993-1-8
- EN 1993-1-4
- EN 1090
- ISO 3506
Quick quote
Send drawings and the project address; we will define the scope together.
Send project details WhatsAppWhat we check
Bolts
Shear, tension, bearing and block tearing.
Screws and rivets
Pull-out, bearing and shear in thin walls.
Welds
Throat size, HAZ reduction, quality class.
Galvanic corrosion
Isolation and detailing.
FEM
Stress concentrations in special parts.
Information for a quote
- Connection drawing or photo
- Loads
- Materials and wall thicknesses
- Fastener type and grade
Deliverables
- Connection report
- Fastener selection
- Revised detail if required
Bolts, Screws & Welds
How many screws does an aluminium profile need?
It depends on load, wall thickness, screw diameter and edge distances. In thin walls the governing value is usually pull-out from the profile, not the screw itself.
Related structural calculations
Anchor, Bracket & Connections
Brackets, welds, bolts and concrete anchors, with manufacturer software and FEM.
Details →Facade Detail Design
Principle and shop details: slab edges, sills, corners, movement joints, fire stopping. DWG delivery.
Details →Steel Substructures
Secondary steel behind facades, cantilevers, canopy and pergola steel supports.
Details →Curtain Wall Structural Calculation
Mullions, transoms, glass, brackets and anchors to EN 1991-1-4, EN 13830 and EN 1999-1-1.
Details →Window, Door & Sliding Systems
Large windows, lift-and-slide and folding doors: profiles, reinforcement, glass and sash weight.
Details →Glass Balcony & Guillotine Glass
Folding glass balconies and guillotine glass: wind, glass thickness, tracks and anchors.
Details →Let’s talk about your project
Send drawings, elevations and system information; we will define the scope and timeline and get back with a quote.