Skylight, glass roof and canopy structural calculation
Overhead glass needs the highest safety level. We check glass, supports and connections of skylights, glass roofs and canopies under snow and wind.
Why it matters
Snow stays on inclined and flat glass while wind creates uplift. Canopies add cantilever action and tie rods to the load path; overhead glass must be laminated with post-breakage capacity.
We check aluminium rafters and glass in skylights, and steel members, welds, tie rods and anchors in steel-supported canopies.
Systems
- Pyramid and ridge skylights
- Atrium glass roofs
- Entrance glass canopies
- Point-fixed glass canopies
- Tie-rod cantilever canopies
Standards
- EN 1991-1-3
- EN 1991-1-4
- DIN 18008-2/-3
- EN 1999-1-1
- EN 1993-1-1
Quick quote
Send drawings and the project address; we will define the scope together.
Send project details WhatsAppWhat we check
Snow and wind
Shape coefficients, drift and canopy net pressures.
Overhead glass
Laminated build-up, stress, deflection, post-breakage.
Supports
Aluminium rafters or steel beams.
Tie rods and spiders
Rods, joints, spider arms and hole regions.
Anchors
Wall and slab connections.
Information for a quote
- Plans, sections, slope
- Glass and fixing type
- Support system
- Address and altitude
Deliverables
- Structural report
- Glass build-up
- Connection details
Skylights, Glass Roofs & Canopies
Can single toughened glass be used in a canopy?
Overhead glazing should be laminated to prevent falling after breakage. Thickness and interlayer are determined by calculation.
Related structural calculations
Curtain Wall Structural Calculation
Mullions, transoms, glass, brackets and anchors to EN 1991-1-4, EN 13830 and EN 1999-1-1.
Details →Window, Door & Sliding Systems
Large windows, lift-and-slide and folding doors: profiles, reinforcement, glass and sash weight.
Details →Glass Balcony & Guillotine Glass
Folding glass balconies and guillotine glass: wind, glass thickness, tracks and anchors.
Details →Structural Glass Calculation
Facade, roof, balustrade and floor glass: stress, deflection and climatic loads on IGUs.
Details →Glass Balustrade Calculation
Channel-clamped and point-fixed balustrades: line load, laminated glass and anchors.
Details →Cladding Substructures
Aluminium substructures for ACP, ceramic, HPL, stone and metal panel cladding.
Details →Let’s talk about your project
Send drawings, elevations and system information; we will define the scope and timeline and get back with a quote.