Glass balcony and guillotine glass structural calculation
On upper floors, glass balconies and guillotine systems carry significant wind load. We size glass, tracks, profiles and anchors by calculation.
Why it matters
Panels in folding systems are held only by rollers and pins in the top and bottom tracks, so track, pin and ceiling anchor capacities become critical.
For guillotine systems the parked position, motor and counterweight are checked; if the lower part acts as a barrier, the horizontal barrier load is included.
Systems
- Folding glass balconies
- Sliding glass balconies
- Motorised and manual guillotine glass
- Restaurant and terrace enclosures
Standards
- EN 1991-1-4
- EN 1991-1-1
- DIN 18008
- EN 1999-1-1
- EN 1992-4
Quick quote
Send drawings and the project address; we will define the scope together.
Send project details WhatsAppWhat we check
Wind
Pressure and suction by height and location.
Glass
Toughened / laminated thickness, stress and deflection.
Tracks and profiles
Track, pin and roller capacities.
Barrier function
Line load where the lower part acts as a barrier.
Anchors
Slab and ceiling fixings.
Information for a quote
- Opening sizes and panel count
- System data
- Glass build-up
- Floor level and address
Deliverables
- Structural report
- Glass and panel width recommendation
- Anchor type and spacing
- Span tables for product ranges
Glass Balcony & Guillotine Glass
From which floor is a calculation needed?
There is no fixed floor limit; wind load depends on location, exposure and height. Tall buildings, open terrain, coastal sites and corner balconies always require a calculation.
Related structural calculations
Curtain Wall Structural Calculation
Mullions, transoms, glass, brackets and anchors to EN 1991-1-4, EN 13830 and EN 1999-1-1.
Details →Window, Door & Sliding Systems
Large windows, lift-and-slide and folding doors: profiles, reinforcement, glass and sash weight.
Details →Structural Glass Calculation
Facade, roof, balustrade and floor glass: stress, deflection and climatic loads on IGUs.
Details →Glass Balustrade Calculation
Channel-clamped and point-fixed balustrades: line load, laminated glass and anchors.
Details →Skylights, Glass Roofs & Canopies
Skylights, glass roofs and suspended canopies: snow, wind, overhead glass and supports.
Details →Cladding Substructures
Aluminium substructures for ACP, ceramic, HPL, stone and metal panel cladding.
Details →Let’s talk about your project
Send drawings, elevations and system information; we will define the scope and timeline and get back with a quote.